FAULT |
CAUSE |
TROUBLESHOOTING METHODS |
Air leakage in the mask |
There is a gap between the mask and face |
Keep the face smooth and clean |
Put on the mask again and adjust the fixing strap |
||
Air leakage at the junction between the mask and demand valve |
1.Clean the junction of fast interface 2.Reconnect 3.Send the cylinder to a designated service center for repair |
|
No air entry or overlarge resistance during breathing |
Cylinder switch is not turned on |
Fully open the cylinder switch |
Demand valve fault |
Use a functional demand valve for replacement |
|
Pressure regulator fault |
Use a functional pressure regulator for replacement |
|
Exhalation valve is insensitive |
Check and clean exhalation valve module |
|
Air leakage at the junction between cylinder valve and nozzle |
1.Reconnect or clean 2.Send the cylinder to a designated service center for repair |
|
Air leakage in the cylinder valve |
Air leakage in the cylinder |
Send the cylinder to a designated service center for repair |
Air leakage in the system |
Air leakage at the junction of the pressure regulator and the cylinder switch |
1.Tighten the connection between the pressure regulator and the cylinder switch 2.Clean the O-ring inside the movable joint of the pressure regulator 3.Send the cylinder to a designated service center for repair |